AFUE, BTU, BTUH, IAQ, CFM…and those are just some of the terms commonly used in heating and cooling that you’ll find here in the glossary. While these may not become part of your everyday vocabulary, they can be helpful to know when investing in new equipment and working with your Bryant® dealer.

A

*Wi-Fi® is a registered trademark of the Wi-Fi Alliance Corporation.

Top

AFUE
Annual Fuel Utilization Efficiency. Indicated as a percentage, your furnace's AFUE tells you how much energy is being converted to heat. For example, an AFUE of 90 means that 90% of the fuel is being used to warm your home, while the other 10% escapes as exhaust with the combustion gases. The higher the AFUE, the higher the efficiency of your furnace.

Top

Advanced Reciprocating Compressor
Type of compressor that uses a more efficient process for compressing refrigerant for better cooling efficiency.

Top

AeroQuiet™ System
Bryant’s AeroQuiet System includes sound-deadening features in the cabinet, fan system and top for better airflow, lower noise and better efficiency.

Top

Air Handler
The portion of your air conditioner or heating system that forces air through your home's ductwork.

Top

Air Purifier
Bryant’s line of whole-home air purifiers treat 100% of the air flowing through your HVAC system before it even circulates, by removing particulates, bacteria and viruses from the air.

Top

B

BTU
British Thermal Unit. Used for both heating and cooling, BTU is a measure of the heat given off when fuel is combusted. Or for cooling, it's a measure of heat extracted from your home. (One BTU is approximately equal to the heat given off by a wooden kitchen match.)

Top

BTUH
A British Thermal Unit (BTU) is the unit of heat required to raise 1 pound of water by 1 degree Fahrenheit. BTUH is British Thermal Units per Hour.

Top

Beckett Burner
A burner assembly within your oil furnace, manufactured by Beckett Corp. to exact specifications of Bryant. This burner provides good combustion of heating oil.

Top

C

CFM
Stands for Cubic Feet per Minute. A measurement of airflow that indicates how many cubic feet of air pass by a stationary point in one minute. The higher the number, the more air is being forced through the system.

Top

Capacity
The ability of a heating or cooling system to heat or cool a given amount of space. For heating, this is usually expressed in BTUs. For cooling, it is usually given in tons.

Top

Carbon Monoxide
A colorless, odorless, highly poisonous gas produced when carbon-based fuels, such as natural gas, burn without sufficient air nearby.

Top

Carbon Monoxide Alarm
A device that reads and detects levels of carbon monoxide in your home. When unsafe levels of CO are present, a loud, high-pitched alarm will sound to alert you.

Top

Cassette Ductless Indoor Unit
An indoor unit that is mounted in the ceiling. These units have four louvers to allow for even air distribution, are compatible with single and multi-zone systems and can be controlled by a remote controller or wired remote controller.

Top

Central Air
Central air-conditioning offers comfort for your whole home. Air is cooled at a central location and distributed throughout your home via a fan and ductwork, as opposed to a window unit, which focuses on a certain room.

Top

Compressor
Part of the heat pump or air conditioner unit that controls the pressure applied to the refrigerant, necessary for taking in heat to warm your home or getting rid of heat to keep your home cool.

Top

Condenser Coil
Part of the outdoor portion of a split-system air conditioner or heat pump. By converting refrigerant that is in a gas form back to a liquid, the coil sends heat carried by the refrigerant to the outside. Also referred to as an outdoor coil.

Top

Continuous Fan Switch
A feature on an oil furnace allowing the furnace’s fan to blow continuously to improve system efficiency and maintain even temperatures.

Top

Control System
Thermostat, Thermidistat™ or Evolution® Connex™ Control device used by homeowner to set temperature and other settings.

Top

D

dB
Decibels (dB) are a unit measuring the intensity of noise.

Top

Damper
A type of "valve" used in ductwork that opens or closes to control airflow. Used in zoning to control the amount of warm or cool air entering certain areas of your home.

Top

Dehumidifier
A device that can be added to your heating and cooling system, that works to draw excess moisture out of indoor air.

Top

Downflow
A type of furnace that takes cool air from the top and blows warm air to the bottom—common where your furnace must be located in a second-floor closet or utility area.

Top

Dual Fuel Heat System
A dual fuel heat system combines the installation of a heat pump with your furnace, giving you two sources to heat your home. The heat pump is primary and the gas furnace kicks in during colder weather if the heat pump can’t meet the heating demands of your home.

Top

Ducted Ductless Indoor Unit
A ductless system where the indoor fan coil is installed within a drop ceiling, attic or crawl space. It circulates air through a specific zone using short run ductwork, allowing a single fan coil to distribute air to several rooms within a zone. These units are compatible with single and multi-zone applications and can be controlled by a remote controller or wired remote controller.

Top

Ductless System
(Also referred to as a duct-free system, ductless split system or mini-split system) A heating and cooling system composed of an outdoor compressor unit connected by refrigerant lines to one or more indoor units, each consisting of a coil and fan. These systems require no ductwork, are flexible in application and are available as single or multi-zone systems.

Top

Ductwork
Hollow pipes used to transfer air from the air handler to the air vents throughout your home. Ductwork is one of the most important components of a home heating and cooling system.

Top

DuraGuard™
DuraGuard is a Bryant innovation that protects outdoor units from weather and increases durability.

Top

DuraGuard Plus™
DuraGuard Plus™ is a Bryant innovation that protects outdoor units from weather and increases durability. DuraGuard Plus™ includes appliance-style fit and finish and a world-class patent pending system.

Top

E

Electronic Air Filter
The electronic air filter can be installed with your heating and cooling systems ductwork to help provide whole-home filtration.

Top

Energy Efficiency Ratio 2 (EER2)
Energy Efficiency Ratio 2 (EER2), is the cooling capacity of an air conditioner or heat pump unit for a specific amount of energy used in a specific testing climate. This standardized rating is important to know because it helps allow you to compare the efficiency of different cooling products.

Top

Electronic Air Cleaner (EAC)
An electronic device that filters out large particles and contaminants in indoor air. It then electronically pulls out tiny particles that have been magnetized, such as viruses and bacteria, drawing them to a collector plate.

Top

Electronic Air Filter
The electronic air filter can be installed with your heating and cooling systems ductwork to help provide whole-home filtration.

Top

Energy Saver Switch
An energy saver switch causes the air conditioner's fan and compressor to cycle on and off together, reducing energy use.

Top

Energy Star®
Energy Star® is a government-backed program helping businesses and individuals protect the environment through superior energy efficiency. Products with the Energy Star rating will be efficient and save cost on energy bills.

Top

Evaporator Coil
Part of a split-system air conditioner or heat pump located indoors. The evaporator coil cools and dehumidifies the air by converting liquid refrigerant into a gas, which absorbs the heat from the air. The warmed refrigerant is then carried through a tube to the outdoor unit (condenser coil). Also referred to as an indoor coil.

Top

F

Fan Coil
An indoor component of a heat pump system, used in place of a furnace, to provide additional heating on cold days when the heat pump does not provide adequate heating.

Top

Fan On Plus
The advanced control intelligence that drives the adjustable constant fan operation on select Bryant furnaces.

Top

Floor Console Ductless Indoor Unit
An indoor unit mounted near the floor that is compatible with single and multi-zone applications .They distribute air out of both the top and lower portion of the front panels (depending on cooling or heating mode) and can be controlled by a remote controller or wired remote controller. These units are well suited for rooms with windows and limited wall space.

Top

Freon™
The trade name Freon™ is a registered trademark belonging to E.I. du Pont de Nemours & Company (DuPont). Production of Freon ceased in 2015 per the Montreal Protocol.

Top

G

Geothermal Heat Pump
Bryant geothermal heat pumps tap into the earth’s surface to use the energy and consistent heat found in the ground, instead of using outside air like traditional heat pumps.

Top

H

HSPF 2
Heating Seasonal Performance Factor 2 (HSPF2) is a standardized rating used by all heat pump manufacturers to compare energy efficiencies between split-system air-source heat pumps. Like miles per gallon for a car, the higher the HSPF 2, the more efficient the system.

Top

HVAC
Term used for Heating, Ventilation, and Air Conditioning.

Top

Heat Exchanger
The part of a furnace that transfers heat to nearby air. That air is then distributed through the ductwork throughout your home.

Top

Heat Pump
A heating and air conditioning unit that heats or cools by moving heat.

Top

High Wall Ductless Indoor Unit
An indoor unit that is mounted on a wall. Location on the wall can be optimized depending on application and efficiency calculations. These units distribute air flow evenly throughout the room, are compatible with single and multi-zone systems and can be controlled by a remote controller or wired remote controller.

Top

Horizontal Flow
A type of furnace, installed on its "side," that draws in air from one side, heats it and sends the warm air out the other side. Most often used for installations in attics or crawl spaces.

Top

Humidifier
A piece of equipment that adds water vapor to heated air as it moves out of the furnace. This adds necessary moisture to protect your furnishings and reduce static electricity.

Top

Humidistat
A control used to manually maintain humidity at a fixed point.

Top

Hybrid Heat®
Hybrid Heat® systems deliver exceptional performance by using a heating source that provides the most energy-efficient comfort during moderate heating conditions.

Top

I

IAQ
Indoor Air Quality (IAQ) refers to the cleanliness and health of the air in a home. IAQ factors include particulate count (pollen, mold), humidity and volatile organic compounds found in a home’s air – all of which can aggravate allergy and asthma symptoms.

Top

Indoor Coil
See Evaporator Coil.

Top

Inverter Compressor
A compressor that continually operates at an optimal level and adapts operating speed to maintain even temperature regulation. Instead of running at 100% capacity to reach the desired temperature and then stopping, the inverter compressor works at lower, consistent levels, reducing temperature swings and on-and-off operation. This technology is similar to cruise control in a car, because it adjusts automatically using only the energy that it is needed to maintain the desired setting.

Top

L

Lineset
Semi-flexible sets of copper pipes or tubing, comprised of a smaller liquid line and larger suction line, used in different HVAC applications to circulate refrigerant. In ductless system applications, a lineset connects the indoor units of a system to the outdoor condensing unit.

Top

Load Estimate
A series of studies performed to determine the heating or cooling requirements of your home. An energy load analysis uses information such as the square footage of your home, window or door areas, insulation quality and local climate to determine the heating and cooling capacity needed by your furnace, heat pump or air conditioner. When referring to heating, this is often known as a Heat Loss Analysis, since a home's heating requirements are determined by the amount of heat lost through the roof, entryways and walls.

Top

Low Boy
Low Boy is a type of furnace configuration in which the furnace is lower in height and occupies more floor space.

Top

M

MERV
The Minimum Efficiency Reporting Value is the standard comparison of the efficiency of an air filter. The MERV scale ranges from 1 (least efficient) to 16 (most efficient), and measures a filter's ability to remove particles from 3 to 10 microns in size.

Top

Matched System
A heating and cooling system comprised of products that have been certified to perform at promised comfort and efficiency levels when used together, and used according to design and engineering specifications.

Top

Multipoise
A multi-direction configuration that allows for both upflow and downflow installations.

Top

Multi-Zone Ductless System
A ductless system where multiple indoor units are connected to and powered by a single outdoor unit. Systems are capable of supporting up to nine indoor units with multiple styles available.

Top

O

Operating Cost
The day-to-day cost of running your home comfort equipment, based on energy use.

Top

Outdoor Coil
See Condenser Coil.

Top

P

Packaged Product
Contrary to a split system, which has both an indoor and outdoor unit, a packaged product is an outdoor unit that contains all the components of the system in a single unit.

Top

Payback Analysis
Overall measure of the efficiency and value of your home comfort system. By combining your purchase price and ongoing operating costs, a payback analysis determines the number of years required before monthly energy savings offset the purchase price.

Top

Perfect Heat® Technology
Perfect Heat® technology provides automated staging of heating to battle changing winter conditions. At start up, low stage heating gently circulates warm, heated air into your living space. As outdoor temperatures become more extreme, Perfect Heat technology stages the level of heating you need to remain comfortable.

Top

Perfect Humidity® Technology
Perfect Humidity® technology ensures optimal summertime cooling dehumidification when system components include multi- and variable-speed cooling products.

Top

PerfectLight™
PerfectLight™ is an advanced gas furnace ignition system that replaces standard pilot lights and improves upon traditional modern igniters used by other manufacturers.

Top

PerfectSense
PerfectSense provides modulating heat to battle changing winter conditions. At start up, the lowest stage heating gently circulates warm, heated air into your living space. As outdoor temperatures become more extreme, the highest stage heating provides the extra boost you need to remain comfortable.

Top

Puron® Refrigerant
Puron® Refrigerant is designed not to harm the earth's ozone layer. Federal law requires all manufacturers phase out ozone-depleting refrigerants beginning January 1, 2025. Puron Refrigerant is approved by the U.S. Environmental Protection Agency as a replacement for R-22.

Top

Q

Top

R

R-22 Refrigerant
R-22 is a single-component HCFC refrigerant with low ozone depletion potential. It has long been used in a variety of air conditioning and refrigeration applications in a variety of markets. Production of R-22 ceased in 2015 per the Montreal Protocol. Also commonly known as Freon.

Top

R-410A Refrigerant
R-410A is a blend of refrigerants with low ozone depletion potential, commonly known as Puron. Production of R-410A will cease in 2025.

Top

Reciprocating Compressor
A type of compressor used in air conditioners that compresses refrigerants by using a type of “piston” action.

Top

Reclaiming
Involves returning used refrigerant to the manufacturer for disposal or reuse.

Top

Recycling
Removing, cleaning and reusing refrigerant.

Top

Refrigerant Lines
Two copper lines that connect the Condenser (Outdoor) Coil to the Evaporator (Indoor) Coil.

Top

Remote Access
Requires Wi-Fi® enabled model connected to a Wi-Fi network. Some models require a dedicated Wi-Fi router.

Top

Remote Room Sensor
When the most convenient location for the main thermostat or control is not best for assessing the average conditions of the home (such as when it’s located near an exterior door), you can apply a remote sensor to feed information about the comfort conditions to the main unit.

Top

Riello Burner
A burner assembly within your oil furnace, manufactured by Riello to exact specifications of Bryant. This burner provides a cleaner, higher-quality combustion of heating oil to increase energy efficiency.

Top

S

SEER 2
The seasonal energy efficiency ratio 2 (SEER2) is used to compare the energy efficiencies of different central air conditioners and heat pump systems. Like miles per gallon for a car, the higher the SEER2, the more efficient the system.

Top

Scroll Compressor
A specially designed compressor that works in a circular motion instead of an up-and-down piston action.

Top

Setback Thermostat
A state-of-the-art electronic thermostat with a built-in memory that can be programmed for different temperature settings at different times of the day.

Top

Single Package
One outdoor unit that contains both a heating and cooling system.

Top

Single Zone Ductless System
A ductless system where one indoor unit is connected to one outdoor unit with multiple indoor unit styles available.

Top

Smart Recovery
Actively manages system ramp up during “away” periods to meet homeowner comfort needs while saving money.

Top

Smart Setback Programming
Uses information about indoor and outdoor conditions and the specifics of the system’s capabilities to determine the best temperature setback during “away” periods and when to ramp up to save energy while staying within homeowner min/max temperature preferences.

Top

Split System
Refers to an air conditioner or heat pump that has components in two locations. Usually, one part of the system is located inside (evaporator coil) and the other is located outside your home (condenser coil).

Top

System Control
Thermostat; Evolution system control device used by homeowner to set temperature and other settings.

Top

T

Thermidistat™ Control
The Thermidistat™ control monitors temperatures both inside and outside, as well as indoor humidity and adjusts system operation to maintain the temperature and humidity levels set by the homeowner.

Top

Thermostat
Unit that monitors and controls your HVAC system products.

Top

Thermostatic Expansion Valve
A thermostatic expansion valve (TXV) is a precision device used to meter the flow of liquid refrigerant entering the evaporator at a rate that matches the amount of refrigerant being boiled off in the evaporator.

Top

Ton
A unit of measure for cooling capacity. One ton = 12,000 BTUs per hour.

Top

Total Home Comfort System
The ultimate solution to providing you with consistent, customized home comfort, despite the ever-changing weather.

Top

TrueSense™ Dirty Filter Detection
TrueSense™ dirty filter detection reminds you when it's time to change your media filter.

Top

U

UL
UL is an objective, non-profit organization that tests and rates electrical products for public safety.

Top

Underceiling Ductless Indoor Unit
An indoor unit mounted near the ceiling. These units are used in single-zone, light commercial applications, are capable of air distribution throughout a larger space, and can be controlled by a remote controller or wired remote controller.

Top

UV Lamps
Bryant UV lamps attack and kill mold and bacteria that can grow on the cooling coil of many HVAC systems, preventing it from circulating through the home.

Top

Upflow
A type of furnace that draws cool air from the bottom and blows the warmed air out the top into the ductwork. This type of furnace is usually installed in a basement or an out-of-the-way closet.

Top

V

Variable-Speed
Technology that allows your system to operate quietly and efficiently at longer, lower speed cycles throughout the day – meaning your system and comfort stay consistent.

Top

VRF (Variable Refrigerant Flow)
An indoor comfort system that adjusts temperature through variable refrigerant flow technology to provide flexible zoning comfort. Indoor units can be controlled independently as the system varies capacity delivered to each zone. Some systems are capable of connecting up to 48 indoor units to a single outdoor condensing unit. All indoor units can be controlled from either a central controller or individual control, depending on application.

Top

Ventilator
A ventilator captures heating or cooling energy from stale indoor air and transfers it to fresh incoming air.

Top

Z

Zoning

A way to increase your home comfort and energy efficiency by controlling when and where heating and cooling occurs in a home. Programmable thermostats are used to control operating times of the equipment. Dampers are used to direct airflow to certain parts or "zones" of the home.

Top