Preferred™ Variable-Speed Geothermal Heat Pump
Extra Savings, Extra Comfort, All Year Long
Our GP geothermal models deliver excellent energy efficiency and comfort thanks to their combination of two-stage compressor and variable-speed blower operation. Enjoy even temperatures, enhanced summer dehumidification and the dependability you expect from Bryant®.
- EER Efficiency Range :
- 15.5 to 24.5 EER (closed loop); 19.6 to 30.0 EER (open loop)
- COP Efficiency Range :
- 3.5 to 4.0 COP (closed loop); 4.0 to 4.6 COP (open loop)
- Compressor Type :
- Two-Stage
Features
- Manage your utility costs with high-efficiency comfort (efficiency is unit size dependent): Closed loop cooling EER - Up to 24.5; Closed loop heating COP - Up to 4.0
- Enjoy the ultra-quiet performance and even-temperature comfort of variable-speed air delivery
- Two-stage scroll compressor operation allows longer, more consistent cycles in lower stage for savings and comfort
- Superior summer dehumidification
- Insulated cabinet and compressor blanket for quiet operation
- Wide operating temperature range with exceptional cold weather performance
- Corrosion-resistant coil for durability
- 2" MERV 8 filtration
- 10-year parts and labor limited warranty1
- Supplemental, domestic hot water generation
- Internally-mounted auxiliary heat
- Smart startup add-on for smoother operation
1. To the original owner, when installed in a residence, a 10-year parts and labor limited warranty upon timely registration of equipment. Warranty period is 10 years on parts and 5 years on labor if not registered within 90 days of installation. Original owners residing in jurisdictions that prohibit warranty benefits conditioned on registration will automatically receive a 10-year parts and labor limited warranty. See warranty certificate for details.
Specifications
EFFICIENCY MANAGEMENT
Cooling Efficiency 15.5 to 24.5 EER (closed loop); 19.6 to 30.0 EER (open loop)
Heating Efficiency 3.5 to 4.0 COP (closed loop); 4.0 to 4.6 COP (open loop)
Heating and Cooling Two-stage operation for efficiency and comfort
ENERGY STAR® ENERGY STAR® qualified in all sizes
SOUND
Quiet Levels Quiet operation enhanced by full cabinet insulation; double-isolation compressor mounting and compressor sound blanket
CONVENIENCES
Filter Cabinet Built-in for easy filter changes
Maintenance Reminders With compatible control
TECHNOLOGY
Blower Motor High-efficiency variable-speed
Compressor Two-stage scroll
Control Board Microprocessor with compressor diagnostic capability
Refrigerant Puron® refrigerant
Refrigerant Management Thermostatic expansion valve
Protection Corrosion-resistant coil protection for long life
INSTALLATION
Positioning Vertical upflow, horizontal or vertical downflow units available
AESTHETICS
Capacity 2-6 tons
Construction Galvanized steel
Paint Baked-on urethane base coat and polyester top coat
Bryant reserves the right to discontinue or change any specification or design without prior notice or obligation.
- Manage your utility costs with high-efficiency comfort (efficiency is unit size dependent): Closed loop cooling EER - Up to 24.5; Closed loop heating COP - Up to 4.0
- Enjoy the ultra-quiet performance and even-temperature comfort of variable-speed air delivery
- Two-stage scroll compressor operation allows longer, more consistent cycles in lower stage for savings and comfort
- Superior summer dehumidification
- Insulated cabinet and compressor blanket for quiet operation
- Wide operating temperature range with exceptional cold weather performance
- Corrosion-resistant coil for durability
- 2" MERV 8 filtration
- 10-year parts and labor limited warranty1
- Supplemental, domestic hot water generation
- Internally-mounted auxiliary heat
- Smart startup add-on for smoother operation
1. To the original owner, when installed in a residence, a 10-year parts and labor limited warranty upon timely registration of equipment. Warranty period is 10 years on parts and 5 years on labor if not registered within 90 days of installation. Original owners residing in jurisdictions that prohibit warranty benefits conditioned on registration will automatically receive a 10-year parts and labor limited warranty. See warranty certificate for details.
EFFICIENCY MANAGEMENT
Cooling Efficiency 15.5 to 24.5 EER (closed loop); 19.6 to 30.0 EER (open loop)
Heating Efficiency 3.5 to 4.0 COP (closed loop); 4.0 to 4.6 COP (open loop)
Heating and Cooling Two-stage operation for efficiency and comfort
ENERGY STAR® ENERGY STAR® qualified in all sizes
SOUND
Quiet Levels Quiet operation enhanced by full cabinet insulation; double-isolation compressor mounting and compressor sound blanket
CONVENIENCES
Filter Cabinet Built-in for easy filter changes
Maintenance Reminders With compatible control
TECHNOLOGY
Blower Motor High-efficiency variable-speed
Compressor Two-stage scroll
Control Board Microprocessor with compressor diagnostic capability
Refrigerant Puron® refrigerant
Refrigerant Management Thermostatic expansion valve
Protection Corrosion-resistant coil protection for long life
INSTALLATION
Positioning Vertical upflow, horizontal or vertical downflow units available
AESTHETICS
Capacity 2-6 tons
Construction Galvanized steel
Paint Baked-on urethane base coat and polyester top coat
Bryant reserves the right to discontinue or change any specification or design without prior notice or obligation.
Documents
California residents please see Proposition 65